Copper Busbars for AI BBU and Energy Storage Racks
Copper busbars for AI battery backup units and energy storage racks.
データセンターバスバー
RHI Rack Busbars are designed for OCP ORv3 Open Rack systems and high-density AI data centers, providing standardized high-current DC power distribution through a laminated busbar structure. With current ratings ranging from 425A to 2900A, they support diverse power requirements for Power Shelves, PSU modules, BBU systems, AI servers, storage, and network switches. Blind-mate connections simplify installation, reduce cabling complexity and voltage drop, while the vertical busbar design helps reduce cable congestion, improve airflow, and simplify rack maintenance. Custom designs are available to meet specific rack configurations and power requirements.
| めっき | 錫めっき, ニッケルめっき |
|---|---|
| 最小発注数量 | 100 |
| サイズ | カスタム |
| 導体材料 | C11000銅 |
| 絶縁 | FR-4ガラスエポキシ板 |
A Rack Busbar is a conductive power distribution component installed inside a server rack. Typically made of copper or aluminum conductors with an insulated structure, it provides a centralized pathway for distributing DC power to multiple rack-mounted devices. Compared with conventional cable-based wiring, its integrated design offers a more structured and space-efficient power distribution solution.
Designed for OCP Open Rack systems, RHI Rack Busbars connect Power Shelves or Power Supply Units (PSUs) to rack-level equipment through dedicated power interfaces. They support power delivery to BBU Shelves, IT servers, storage systems, and network switches. With voltage ratings from 48VDC to 54VDC and current ratings from 425A to 2900A, the series meets various ORv3 rack power requirements while helping simplify installation, reduce cable congestion, and improve rack-level power integration.
RHI ORv3 Vertical Busbars are designed for OCP ORv3 Open Rack systems, providing high-current DC power distribution through a laminated busbar structure. With current ratings from 425A to 2900A, they accommodate different rack power requirements and distribute power to Power Shelves, PSU modules, BBU systems, AI servers, storage systems, and network switches. The integrated busbar architecture provides a structured alternative to conventional cable-based distribution, helping reduce wiring complexity and voltage drop.
Designed for blind-mate connections, RHI ORv3 busbars simplify power interfaces between rack components, reducing manual cabling and installation work. The vertical layout helps minimize cable congestion, preserves airflow paths, and improves access for rack maintenance. Custom busbar dimensions, connection interfaces, and current ratings can be developed to match specific rack configurations and power distribution requirements.
| めっき | 錫めっき, ニッケルめっき |
|---|---|
| 最小発注数量 | 100 |
| サイズ | カスタム |
| 導体材料 | C11000銅 |
| 絶縁 | FR-4ガラスエポキシ板 |
OCP Server Racks and Custom-Designed Server Racks
曲げ、打ち抜き、溶接、リベット、ディップは社内で行い、ロボットで能力を上げています。プロジェクトチームがコストと接続の安定を支えます。
図面、電流、年間数量をお送りください。楽清の担当が営業時間内に返信します。