Designed for heavy-duty lithium-ion forklift battery packs, this busbar assembly combines a lightweight aluminum busbar with a copper-aluminum transition terminal, providing an efficient balance of weight reduction and electrical performance. The aluminum conductor helps reduce the overall battery pack weight and cost, while the copper terminal ensures a reliable copper-to-copper connection with the battery negative post. The integrated structure delivers low-resistance power transmission and durable mechanical performance, making it a practical solution for high-current battery interconnections under demanding operating conditions.

Vật liệu dẫn C11000 Copper, 1060 Aluminum
Busbar Dimensions theo yêu cầu to drawing and application requirements.
Weld Zone Shear Strength ≥ 2,500 N
Pull-Out Force Material Tensile Strength × Aluminum Busbar Cross-Sectional Area × 0.3
Insulation Options EVA/PE Heat-Shrink Tubing
Precision Machining & Finishing Bending, surface polishing, edge rounding, precision punching, and deburring.

Copper-Aluminum Busbars for Lithium Forklift Batteries

Lithium forklift batteries typically operate for 8–12 hours per shift, requiring busbars to withstand continuous current, heat buildup, vibration, and mechanical shock.

RHI copper-aluminum busbars combine a lightweight aluminum body with copper connection terminals, balancing electrical performance, structural requirements, and material efficiency. This hybrid design reduces overall weight and enables cost optimization without compromising the required electrical connection performance.

Custom-engineered to meet specific pack layouts, current ratings, and installation requirements, RHI busbars provide reliable power distribution and help reduce maintenance needs over the battery pack’s service life.

Custom Engineering Includes:

  • Cross-Section: Designed for required current capacity and thermal performance.

  • Copper Terminals: Matched to battery terminal specifications.

  • Mounting Holes: Positioned to fit the battery module layout.

  • Welded Joint: Located according to structural and installation requirements.

Copper-Aluminum Composite Busbar Design

RHI joins the rigid aluminum busbar to a copper transition terminal through butt welding, creating a reliable connection that combines the properties of both materials.

The copper terminal connects directly to the battery’s negative terminal, creating a copper-to-copper interface. This design avoids direct copper-aluminum contact at the battery connection point, helping minimize the risk of galvanic corrosion.

The result is a lightweight, cost-optimized busbar solution with reliable electrical connections for lithium forklift battery packs.

Copper-Aluminum Composite Busbar Design

Product Features

  • Lightweight Design
  • Cost Optimization
  • Reliable Copper Terminals
  • Strong Metallurgical Bond
  • Custom Dimensions
 
Copper-Aluminum Busbars
Conductor Material Electrical Conductivity Weld Zone Shear Strength Pull-Out Force
C11000 Copper, 1060 Aluminum 62% IACS ≥ 2,500 N Material Tensile Strength × Aluminum Busbar Cross-Sectional Area × 0.3

FAQ

Q1: Why not use all-copper busbars for forklift battery packs?

All copper busbars offer excellent conductivity but add considerable weight and material cost. Our copper-aluminum composite design uses copper at terminal connection points and aluminum for the main conductor sections, reducing overall weight while maintaining reliable electrical performance. Cross-sections, terminal positions, and copper lengths are customized to each battery pack.

Q2: Will welded joints generate more heat than bolted connections under high current?

Not necessarily. A properly welded copper-aluminum joint provides a metallurgical connection without relying on bolted contact pressure. Its electrical resistance and temperature rise depend on weld quality, joint design, and conductor sizing. We recommend resistance and temperature-rise testing under specified operating conditions.

Q3: Can copper-aluminum welded joints withstand forklift vibration?

Joint reliability depends on weld integrity, geometry, stress concentration, and mounting conditions. Proper structural support helps reduce vibration-induced stress on the welded interface. Vibration and fatigue testing under representative operating conditions is recommended for validation.

Q4: Can the copper terminal be welded to the battery terminal?

Yes, provided the materials and joint design are compatible with the selected welding process. For applications requiring disassembly, bolted connections may be preferred.

RHI offers customized terminal dimensions, thickness, hole positions, and surface finishes to meet specific connection requirements and ensure reliable electrical and mechanical performance.

Copper-Aluminum Busbars

Liên hệ

Gửi bản vẽ, dòng điện hoặc sản lượng năm. Đội Yueqing trả lời trong giờ làm việc.

AttachmentChưa chọn tệpPDF, JPG, PNG, Word, Excel, DWG, STP. Up to 5 files, 10 MB each.

Về chúng tôi

Thành lập năm 2011 tại Yueqing, Chiết Giang. Dòng giới thiệu công khai là Busbar Solutions Expert.