High-Current Data Center Busbar Solutions for AI and OCP ORv3 Systems
As AI workloads drive higher power densities in modern data centers, power distribution systems must deliver higher current capacity, lower electrical losses, and reliable connections within increasingly compact rack architectures.
RHI provides engineered data center busbar solutions for OCP Open Rack, ORv3, and other high-density computing systems. Our busbar solutions support power distribution across power shelves, PSU modules, BBU/CBU systems, PCS, servers, storage, and network switches. Designed around specific electrical, mechanical, and installation requirements, our solutions help simplify power interconnections, optimize rack space, and support reliable DC power delivery.
1. High-Density Rack Power Busbars
The Power Distribution Busbar features low-resistance conduction and reliable insulation for high-current, low-loss power interconnection. Its compact design supports customized dimensions and mounting options for high-power-density racks.
- Supports 12-48 VDC busbar systems
- 18–100 kW rated power
- Reliable insulation, low resistance
- Supports compact 1U configurations, custom form factors, and thin copper profiles.
- OCP Open Rack / BBU & PCS Racks
- Power Shelf / BBU Shelf / CBU Shelf
- PSU / PDU Power & Distribution Systems
- AI Data Centers & HPC Systems
- Server Racks & DC Power Distribution
2. OCP ORv3 Rack Busbars
The Air-Cooled Rack Busbar is designed for OCP Open Rack / ORv3 data center racks, supporting DC power interconnection for Powershelf, PSU, BBU/CBU Shelf, servers, storage, and network switches. Supports 48–54 VDC and 425–2900 A for high-density rack power distribution.
- 48–54 VDC Busbar Interconnection
- Rated Current: 425 / 700 / 1200 / 1400 / 2900 A
- Recommended Rack Height: 440U–500U
- Plated Copper for Reliable Connections
- OCP ORv3 48V DC Busbar Geometry, Compatible with Multiple Connector Ratings
Ideal for
- OCP Open Rack / ORv3 Server Racks
- Power shelf / PSU Power Systems
- BBU Shelf & Rack Power Systems
- IT Servers, Storage & Network Switches
- Custom Data Center Racks
3. 5000A Liquid-Cooled Rack DC Busbar
As rack power density increases, liquid-cooled rack busbars offer enhanced thermal performance over conventional forced-air cooling. Integrated with liquid-cooled rack systems, they improve heat transfer at the busbar and shelf levels for more efficient cooling and power delivery in high-density data centers.
Features
-
Temperature Rise: <30°C (All Operating Conditions)
-
Voltage Drop: <0.1 V @ 440U Rack Height
-
Pressure Drop: <40 PSI @ 440U, 5 LPM
-
Operating Voltage: 48–54 V DC
- Rated Current: 5,000 A, Maximum Custom Current: 10,000 A
-
Recommended Flow Rate: 0.15–5 LPM (Max. 1.32 GPM); IEC 62368-1 G.15 Compliant; Leak-Resistant, Non-Contaminating, Corrosion-Resistant
Application: OCP liquid-cooled data center racks for high-power-density servers and rack-level DC power systems, combining high-current power delivery with liquid cooling.